Code du produit : MS-VFD2A7MS43MNSAA

(MS300) 1HP (HD 2.7A) / 1.5HP (ND 3.6A), 3 Ø 460VAC, 0-599.0Hz (op), (V/Hz, SVC, PM), IP66, Frame A1

VFD-MS300, 1HP, 0.75kW, 460V, (HD 2,7A), (ND 3,0A), 3ph, NEMA4X, 599Hz, Frame A1

Informations supplémentaires :

FEATURES: • Volt/Hertz, Sensorless Vector • Suitable for Induction motors (IM), Interior Permanent Magnet motor (IPM), & Surface Permanent motors (SPM). • All MS300 drives are Heavy Duty and Normal Duty rated. • Compact design saves 40% space compared to existing models • Voltages available: - 115Vac 1 phase input, 230Vac 3 phase output (HD 1/4 ~ 1HP) - 230Vac 1 phase input, 230Vac 3 phase output (HD 1/4 ~ 3HP) - 230Vac 3 phase input, 230Vac 3 phase output (HD 1/4 ~ 20HP) - 460Vac 3 phase input, 460Vac 3 phase output (HD 1/4 ~ 30HP) - 575Vac 3 phase input, 575Vac 3 phase output (HD 1 ~ 10HP) • Programmable (0 ~ 599Hz) for high speed applications. • Delivers 200% High Starting Torque with low speed control of 0.5Hz (IM), 0.0Hz (PM). • IP 20, IP21 with optional conduit box • Conformal coated circuit boards, conforms to IEC60721-3-3, class 3C2. • Adaptable to 50°C environment. • RFI switch for IT mains • Deb Deceleration Energy Back function • Built in Application Macros Compressor, Fan, Pump, Conveyor, Packaging, Textiles & Machine Tool for Fast Startup • Realtime clock & calendar functions. • Built-in 2K step capacity PLC. • The output current is adjustable up to 120% of the drive’s nominal capacity. • All MS300 series drives have built-in dynamic braking transistors. • Quick connect spring set control terminals. • Digital Inputs: 9, (2 dedicated (STO) & 7 programmable), NPN or PNP configurable. • Power removal safety (Safe Torque Off), function for Emergency Stop.’ • 2 Analog Inputs, selectable (0 ~ 10V,-10 ~ +10V, 0 ~ 20ma, 4 ~ 20ma, PTC thermistor & RTD PT100) • Digital Outputs: 1 dry contact (1 NO, 1 NC), 2 open collector transistors & 1 digital frequency ouput. • Analog Outputs: 1; programmable, selectable 0 ~ 10V, 0 ~ 20ma or 4 ~ 20ma. • Communication serial ports: Channel 1 USB, Channel 2 RS-485, (RJ-45 & SG+, SG-, SGND terminals) • Resident communication protocol: Modbus RTU & ASCII. • Optional communication protocols: Profibus DP, DeviceNet, Modbus TCP, Ethernet/IP & CANopen • 1 option card slot: 1 for communication cards

Documents à télécharger :

Contactez-nous
Appelez-nous ou envoyez-nous un courriel pour obtenir plus d'information