• Meets IEEE-841 standard for severe duty motor applications; Meets General Motors® GM® 7E-TA automotive duty specification and Meets IEEE45 USCG marine duty, API RPI4F for offshore platforms • IP-56 cast iron, Meets or exceeds NEMA Premium® efficiencies, NEMA Premium models are in compliance with EISA2007; Actual test and vibration data supplied with each motor • MAX GUARD® Class F Insulation System, Inverter duty 10:1 variable torque and 10:1 constant torque & 1.15 service factor on Sine Wave Power 1.0 SF on Inverter Power • F1/F2 capable, Precision balanced to .08”/sec, Steel conduit box • Inpro/Seal® VBX® bearing isolators on drive end shaft extension TENV and on both ends of TEFC • Modifications and Kits are available • 40°C Ambient 1.15SF Sine Wave Power and 1.0SF inverter power; NOTE: BCP (-P) models are not Hazardous Duty® motors certified for Division 2 locations • Provisions to add stub shaft for an encoder (182-449T, TEFC only, Modifications and Kits are available • Division 2 Class 1 Groups A, B, C, D, T2B • UL® Recognized & CSA certified and CE® Mark